If the pilot light doesn t stay lit check the gas water heater thermocouple by keeping the pilot button depressed.
Water heater thermocouple tester.
The reading should be between 25 and 30.
Thomas seeback discovered it in 1821.
If you can t light the pilot the problem most likely lies with the gas control valve or the gas flow itself not the thermocouple.
If the thermocouple is working you should be able to measure 30 to 40 millivolts of voltage at the connection end of the tube when the pilot flame is on.
It is comprised of two different types of metal which react differently to heat and expand at different rates signaling to the water heater when to turn on or off.
Pilot light keeps going out.
For testing a thermocouple you first have to remove it from the furnace water heater or gas appliance where it is installed.
A thermocouple is a safety device for a standing pilot gas system.
To make certain the thermocouple is bad you have to test it.
The water heater thermocouple is a device that monitors temperatures in the water heater to determine whether it needs to heat up or turn off the heat.
How to test a thermocouple.
Usually a lighter will suffice for the test.
A gas water heater in boise baton rouge buffalo or boston uses a thermocouple that includes a probe attached to a copper tube that screws into a port on the gas valve.
Measure the current by using the multimeter device set on millivolts.
Once it is removed you will need a multimeter that needs to have the ability to read millivolts and a source of fire.
One probe of the meter should be connected to the copper sheath of the thermocouple and the other to the gas valve.
Here s how to test a suspected thermocouple in a gas operated water heater.
Thermocouple thermometer 50 300 degree industrial temperature meter j k t e n r s type thermocouple dual channel temperature meter tester lcd backlight 3 9 out of 5 stars 7 22 99 22.
Originally it had a ratio of copper and nickel and was labeled a coppel copper nickel element.
How to test a thermopile s voltage using a multimeter.
Anything under or hovering around the 20 millivolts mark means the thermocouple needs to be replaced.
Light the pilot by pressing and holding the pilot light button on the gas control valve.
In the early 1900s honeywell applied it to the safety gas valve.
A faulty thermopile may be at fault.