Steam boiler use water level indication to detect the water level in steam drum.
Water level indicator in steam boiler.
Water level indicator consists of three cock as steam cock water cock drain cock and glass tube.
Water level indication and boiler water levels.
The drain cock is used to drain out the water in from glass tube at interval to ensure that the.
Where the boiler drum is situated at considerable height from the floor the water gauge is often inclined to make the water level visible from any position.
When the water being heated in the boiler transforms into steam the level of water in the boiler shell goes.
Low water alarm for safe boiler operation the low water alarm ensures that the combustion of fuel does not continue if the water level in the boiler has dropped to or below a predetermined level.
For automatically controlled steam boilers national standards usually call for two independent low level alarms to ensure safety.
A lot of rules determine to use and arrange two gauge glasses especially for steam boiler which has maximum allowable working pressure above 400 psi or above 28 bar to reduce possibility of breakage which can cause the operator in danger.
It includesmost steam boilers the exception being those of the once through or coil type where there is no steam drum.
Steam drum usually uses gauge glass as its indicator.
Water level indication applies to steam boilers where the water level can be detected.